Mouse IgG1 Negative control, conjugated with Cy5-PE


Catalogue number: X1065

CloneZX3
Product Type Single-Color Negative Control
Units100 Tests
HostMouse
Application Flow Cytometry
Product Form
RPE-Cy-5

Background
Negative control for Immunofluorescence staining with Pure, FITC, Biotin, PE and APC of mouse monoclonal antibodies. Assessment of non-specific binding of mouse monoclonal antibodies to human cell surface antigens.

Purification Method
Purified from mouse ascetic fluid by affinity chromatography.

Concentration
Titered for flow cytometry

Formulation
Provided as sterile filtered solution in phosphate buffered saline with 0.08% sodium azide and 0.2% carrier protein

Functional Analysis
Flow Cytometry Staining

Applications
Consult the appropriate fact sheet to determine the amount of antibodies to be used as a control for PBMC or Whole Blood. PBMC: Add 10 µl of MAB/10^6 PBMC in100 µl PBS. Mix gently and incubate for 15 minutes at 2º to 8ºC. Wash twice with PBS and analyze. WHOLE BLOOD: Add10µl of MAB/100 µl of Whole Blood. Mix gently and incubate for 15 minutes at room temperature 20ºC. Lyse the whole blood. Wash once with PBS and analyze. See instrument manufacturer’s instructions for Lysed Whole Blood and Immunofluorescence analysis with a flow cytometer or microscope. ALLOPHYCOCYANIN: (APC) conjugates are analyzed in multi-color flow cytometry with instruments equipped with a second laser and proper filters. Laser excitation is at α633 nm with a Helium Neon (HeNe) laser or a 600-640 nm (633nm) range for a Dye laser. Peak fluorescence emission is at 660 nm. RPE-Cy-5+: Excites at 488nm and emits at 670nm. Store protected from light.

Storage
Product should be stored at 4-8ºC. DO NOT FREEZE

Ship Conditions
Room Temperature

Product Stability
Reagents are stable for the period shown on the vial label when stored properly

References
1. Immunofluorescence Measurement in a Flow Cytometer using Low-Power Helium Neon Laser Excitation. Shapiro, H.M, Glazer, A.N., Christenson, L., Williams, J.M., and Strom, T. B. Cytometry 4,276, 1983. 2. Comparison of Helium Neon and Dye lasers for Excitation of Allophycocyanin. Loken, M.R., Kiej, J.F. and Kelly, K.,A. Cytometry 8, 96, 1987. 3. Protection of Laboratory Workers from occupationally acquired infections. Second edition; approved guideline (2001). Villanova PA: National Committee for Clinical Laboratory Standards; Document M29-A2. 4. Procedures for the collection of diagnostic blood specimens by venipuncture- approved standard; Fifth edition (2003). Wayne PA: National Committee for Clinical Laboratory Standards; Document H3-A5. 5. Clinical applications of flow cytometry: Quality assurance and immunophenotyping of lymphocytes; approved guideline (1998). Wayne PA: National Committee for Clinical Laboratory Standards; Document H42-A. Cy-5 + Portions of this product is manufactured under license from Carnegie Mellon University, U.S. Patent Number 5,268,486.

Caution
This product is intended FOR RESEARCH USE ONLY, and FOR TESTS IN VITRO, not for use in diagnostic or therapeutic procedures involving humans or animals.

Mouse IgG1 Negative control, conjugated with Cy5-PE

$129.00